听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览INVESTIGATIVE RADIOLOGY期刊下所有文献
  • Assessment of large bowel motility by cine magnetic resonance imaging using two different prokinetic agents: a feasibility study.

    abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000183054.43131.a8

    authors: Buhmann S,Kirchhoff C,Wielage C,Mussack T,Reiser MF,Lienemann A

    更新日期:2005-11-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Interference of gadolinium-containing contrast-enhancing agents with colorimetric calcium laboratory testing.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the extent to which various commercially available gadolinium-containing contrast-enhancing (CE) agents can interfere with the measurement of calcium levels by currently used laboratory methods, suggesting (spurious) hypocalcemia or hypercalcemia with a potential ris...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000170447.45577.5e

    authors: Löwe A,Balzer T,Hirt U

    更新日期:2005-08-01 00:00:00

  • Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000167421.83203.4e

    authors: Diekmann F,Diekmann S,Jeunehomme F,Muller S,Hamm B,Bick U

    更新日期:2005-07-01 00:00:00

  • Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers.

    abstract:RATIONALE AND OBJECTIVE:The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers. MATERIALS AND METHODS:Thirty patients with biopsy-confirmed breast cancers with tumor diameters of 15 mm or smaller (range, 5-15 mm; media...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000166935.56971.ff

    authors: Pfleiderer SO,Marx C,Camara O,Gajda M,Kaiser WA

    更新日期:2005-07-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • The importance of end-systole for optimal reconstruction protocol of coronary angiography with 16-slice multidetector computed tomography.

    abstract:OBJECTIVES:Multidetector-row computed tomography coronary images are usually analyzed in mid-diastole (MD). Because of slow coronary motion also in end-systole (ES), we evaluated the impact on image quality of including ES images and defined an efficient reconstruction protocol. MATERIAL AND METHODS:In 50 coronary mul...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000153930.34439.e4

    authors: Sanz J,Rius T,Kuschnir P,Fuster V,Goldberg J,Ye XY,Wisdom P,Poon M

    更新日期:2005-03-01 00:00:00

  • Effect of inspiratory and expiratory breathhold on pulmonary perfusion: assessment by pulmonary perfusion magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS:Nine healthy v...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000149252.42679.78

    authors: Fink C,Ley S,Risse F,Eichinger M,Zaporozhan J,Buhmann R,Puderbach M,Plathow C,Kauczor HU

    更新日期:2005-02-01 00:00:00

  • Manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging of acute reperfused myocardial injury in a cat model: part I: comparison with pathologic examination.

    abstract:RATIONALE AND OBJECTIVES:To investigate the capacity of manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) to discriminate the injured myocardium from the normal myocardium in a cat model. MATERIALS AND METHODS:Fourteen cats were prepared for acute myocardial infarction with 90-minute...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kim TH,Yang DH,Choi JW,Kim ST,Yoon JH,Shin JH,Seo JB,Gong GY,Lim TH

    更新日期:2005-01-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000138091.96320.f8

    authors: Hamer OW,Völk M,Zorger N,Borisch I,Büttner R,Feuerbach S,Strotzer M

    更新日期:2004-10-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Quantitative evaluation of perfusion and permeability of peripheral tumors using contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS:Normal and tumor-bearing (R3230AC) Fischer ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01rli.0000124456.82985.35

    authors: Pollard RE,Garcia TC,Stieger SM,Ferrara KW,Sadlowski AR,Wisner ER

    更新日期:2004-06-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • Inhibition of restenosis in stented porcine coronary arteries: uptake of Paclitaxel from angiographic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000116125.96544.64

    authors: Speck U,Scheller B,Abramjuk C,Grossmann S,Mahnkopf D,Simon O

    更新日期:2004-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • A new animal model for testing renal tolerance of contrast agents.

    abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000087096.61127.13

    authors: Krause W,Gilles T

    更新日期:2003-11-01 00:00:00

  • Magnetic resonance imaging and histologic findings of experimental cerebral fat embolism.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine whether cerebral fat embolism demonstrated reversible or irreversible findings in magnetic resonance (MR) imaging over time and to compare the features in MR images with histologic findings in a cat model. MATERIALS AND METHODS:MR images were obtained...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000077055.48406.e2

    authors: Kim HJ,Lee CH,Lee SH,Moon TY

    更新日期:2003-10-01 00:00:00

  • New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000077124.24140.bd

    authors: Lawaczeck R,Diekmann F,Diekmann S,Hamm B,Bick U,Press WR,Schirmer H,Schön K,Weinmann HJ

    更新日期:2003-09-01 00:00:00

  • High-resolution magnetic resonance imaging at 2 Tesla: potential for atherosclerotic lesions exploration in the apolipoprotein E knockout mouse.

    abstract:INTRODUCTION:The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS:A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000067491.31978.1c

    authors: Chaabane L,Soulas EC,Contard F,Salah A,Guerrier D,Briguet A,Douek P

    更新日期:2003-08-01 00:00:00

  • Diffusivity- and T2 imaging at 3 Tesla for the detection of degenerative changes in human-excised tissue with high resolution: atherosclerotic arteries.

    abstract:RATIONALE AND OBJECTIVES:We investigated whether it is possible to investigate degenerative changes in human tissue on a sub-100-microm resolution scale not only on special high-field small-bore MR-microscopy systems but also on a 3T whole-body MR-scanner. METHODS:Spin-spin relaxation, proton density, and diffusion mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000068620.17569.83

    authors: Berg A,Sailer J,Rand T,Moser E

    更新日期:2003-07-01 00:00:00

  • Helium3 polarization using spin exchange technique: application to simultaneous pulmonary ventilation/perfusion imaging in small animals.

    abstract:RATIONALE AND OBJECTIVES:To develop a simple and robust helium3 polarization system dedicated to small animal imaging. To demonstrate the potential of helium3 imaging for pulmonary ventilation and perfusion studies. METHODS:A home-built polarization system based on spin-exchange technique was used. This system was app...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Stupar V,Berthezène Y,Canet E,Tournier H,Dupuich D,Crémillieux Y

    更新日期:2003-06-01 00:00:00

  • Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

    abstract:RATIONALE AND OBJECTIVE:To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. MATERIALS AND METHODS:Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000055289.97726.B1

    authors: Mao S,Child J,Carson S,Liu SC,Oudiz RJ,Budoff MJ

    更新日期:2003-03-01 00:00:00

  • Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200302000-00002

    authors: Suga K,Ogasawara N,Yuan Y,Okada M,Matsunaga N,Tangoku A

    更新日期:2003-02-01 00:00:00

  • Comparison of open- and closed-chest canine model for quantification of coronary stenosis severity by myocardial contrast echocardiography.

    abstract:RATIONALE AND OBJECTIVES:The objective of the present study was to compare the data regarding the ability of real-time myocardial contrast echocardiography (MCE) to assess altered myocardial blood flow produced by graded coronary stenoses between open- and closed-chest canine models. MATERIALS AND METHODS:Three grades...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200301000-00006

    authors: Masugata H,Peters B,Lafitte S,Yao B,Strachan M,Ling Kwan O,Ohmori K,Mizushige K,Kohno M

    更新日期:2003-01-01 00:00:00

  • Optimizing an ultrasound contrast agent's stability using in vitro attenuation measurements.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the changes in the microbubble population of a currently available ultrasound contrast agent (USCA) through attenuation measurements to optimize its clinical use. MATERIALS AND METHODS:The microbubble population from a galactose-based USCA (Levovist, Schering AG, Germany) was chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200212000-00006

    authors: Correas JM,Kurtisovski E,Bridal SL,Amararene A,Hélénon O,Berger G

    更新日期:2002-12-01 00:00:00

  • Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi.

    abstract:RATIONALE AND OBJECTIVES:New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200211000-00001

    authors: Schumann PA,Christiansen JP,Quigley RM,McCreery TP,Sweitzer RH,Unger EC,Lindner JR,Matsunaga TO

    更新日期:2002-11-01 00:00:00

  • Nonionic contrast media iohexol and iomeprol decrease renal arterial tone: comparative studies on human and porcine isolated vascular segments.

    abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200208000-00005

    authors: Uder M,Humke U,Pahl M,Jansen A,Utz J,Kramann B

    更新日期:2002-08-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • An overview of neck node sonography.

    abstract:RATIONALE AND OBJECTIVES:Gray scale and power Doppler sonography are commonly used to evaluate cervical lymph nodes. This study was undertaken to identify which of the features used in ultrasound of cervical lymph nodes is readily applicable in routine clinical practice. METHODS:Two hundred and eight-six patients diag...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200206000-00005

    authors: Ahuja A,Ying M

    更新日期:2002-06-01 00:00:00

  • Antiproliferative effects of the antiallergic agent azelastine on human aortic smooth-muscle cells: an in vitro study.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200205000-00002

    authors: Schöber W,Wiskirchen J,Kehlbach R,Gebert R,Rodegerdts E,Betsch A,Johst U,Feuls R,Claussen CD,Duda SD

    更新日期:2002-05-01 00:00:00

  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla.

    abstract:RATIONALE AND OBJECTIVES:To compare the diagnostic efficacy of a standard dose of MRI contrast agent in the evaluation of primary brain tumors and metastases using a high-field 3 tesla MR unit versus a 1.5 tesla MR unit. METHODS:Sixteen patients with brain tumors were examined at both field strengths using identical a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200203000-00003

    authors: Nöbauer-Huhmann IM,Ba-Ssalamah A,Mlynarik V,Barth M,Schöggl A,Heimberger K,Matula C,Fog A,Kaider A,Trattnig S

    更新日期:2002-03-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200112000-00004

    authors: Maintz D,Fischbach R,Juergens KU,Allkemper T,Wessling J,Heindel W

    更新日期:2001-12-01 00:00:00

  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

495 条记录 5/13 页 « 12345678...1213 »